A new study describes how a novel biomedical imaging system converts absorbed optical energy into an acoustic signal that can be detected by ultrasound transducer.
Researchers at Purdue University (Lafayette, IN, USA) have created a motorized photoacoustic tomography (PAT) holder that allows users to easily maneuver and aim the device in order to tune the depth where light is focused, improving light penetration depth and signal-to-noise ratio (SNR) by reducing probe-skin reflection artifacts and improving light distribution in the image acquisition plane. This is achieved by tuning fiber orientation, thus reducing the attenuation of incident light by soft tissues.
The researchers then validated the motorized PAT probe through ex-vivo (laboratory) Monte Carlo simulations and imaging of a tissue mimicking phantom, and in-vivo imaging of murine periaortic fat. Overall, the ex-vivo results showed a several millimeter improvement in penetration depth, with in-vivo results showing a 62% increase in lipid SNR. The PAT probe also utilized a 7-μm aluminum filter to block probe-skin reflection artifacts. The study was published on August 28, 2018, in Photoacoustics.
“The nice thing about photoacoustic tomography is the compositional information. Using photoacoustic tomography for intraoperative tumor biopsies could help surgeons make sure they remove all the cancer from a patient,” said lead author Craig Goergen, PhD, of the Weldon School of Biomedical Engineering at Purdue. “Among other potential uses for photoacoustic tomography is the mapping of lipid deposition within an arterial wall that can cause other health problems, measuring cardiac tissue damage, and tumor biopsies.”
PAT uses non-ionizing laser pulses delivered into biological tissues. Some of the delivered energy is absorbed and converted into heat, leading to transient thermoelastic expansion, and thus wideband ultrasonic emission, which can be detected by transducers and analyzed to produce images. The magnitude of the photoacoustic signal is proportional to the local energy deposition, which can be demonstrated by optical absorption contrast on the images of the targeted areas.
Related Links:
Purdue University
Researchers at Purdue University (Lafayette, IN, USA) have created a motorized photoacoustic tomography (PAT) holder that allows users to easily maneuver and aim the device in order to tune the depth where light is focused, improving light penetration depth and signal-to-noise ratio (SNR) by reducing probe-skin reflection artifacts and improving light distribution in the image acquisition plane. This is achieved by tuning fiber orientation, thus reducing the attenuation of incident light by soft tissues.
The researchers then validated the motorized PAT probe through ex-vivo (laboratory) Monte Carlo simulations and imaging of a tissue mimicking phantom, and in-vivo imaging of murine periaortic fat. Overall, the ex-vivo results showed a several millimeter improvement in penetration depth, with in-vivo results showing a 62% increase in lipid SNR. The PAT probe also utilized a 7-μm aluminum filter to block probe-skin reflection artifacts. The study was published on August 28, 2018, in Photoacoustics.
“The nice thing about photoacoustic tomography is the compositional information. Using photoacoustic tomography for intraoperative tumor biopsies could help surgeons make sure they remove all the cancer from a patient,” said lead author Craig Goergen, PhD, of the Weldon School of Biomedical Engineering at Purdue. “Among other potential uses for photoacoustic tomography is the mapping of lipid deposition within an arterial wall that can cause other health problems, measuring cardiac tissue damage, and tumor biopsies.”
PAT uses non-ionizing laser pulses delivered into biological tissues. Some of the delivered energy is absorbed and converted into heat, leading to transient thermoelastic expansion, and thus wideband ultrasonic emission, which can be detected by transducers and analyzed to produce images. The magnitude of the photoacoustic signal is proportional to the local energy deposition, which can be demonstrated by optical absorption contrast on the images of the targeted areas.
Related Links:
Purdue University
Latest Ultrasound News
- Largest Model Trained On Echocardiography Images Assesses Heart Structure and Function
- Groundbreaking Technology Enables Precise, Automatic Measurement of Peripheral Blood Vessels
- Deep Learning Advances Super-Resolution Ultrasound Imaging
- Novel Ultrasound-Launched Targeted Nanoparticle Eliminates Biofilm and Bacterial Infection
- AI-Guided Ultrasound System Enables Rapid Assessments of DVT
- Focused Ultrasound Technique Gets Quality Assurance Protocol
- AI-Guided Handheld Ultrasound System Helps Capture Diagnostic-Quality Cardiac Images
- Non-Invasive Ultrasound Imaging Device Diagnoses Risk of Chronic Kidney Disease
- Wearable Ultrasound Platform Paves Way for 24/7 Blood Pressure Monitoring On the Wrist
- Diagnostic Ultrasound Enhancing Agent to Improve Image Quality in Pediatric Heart Patients
- AI Detects COVID-19 in Lung Ultrasound Images
- New Ultrasound Technology to Revolutionize Respiratory Disease Diagnoses
- Dynamic Contrast-Enhanced Ultrasound Highly Useful For Interventions
- Ultrasensitive Broadband Transparent Ultrasound Transducer Enhances Medical Diagnosis
- Artificial Intelligence Detects Heart Defects in Newborns from Ultrasound Images
- Ultrasound Imaging Technology Allows Doctors to Watch Spinal Cord Activity during Surgery