Scientists Propose New Ultrasound Video Process Using a Wavelet Variational Model
By MedImaging International staff writers Posted on 17 May 2016 |
Image: The image shows selected, original, ultrasound images and the results of Region of Interest (ROI) tracking using a wavelet variational model (Photo courtesy of Xiaoqun Zhang).
Scientists have developed a new ultrasound video image segmentation model that can be used in medical image analysis to recognize Regions of Interest (ROI) and facilitate the interpretation of ultrasound images.
Real-time applications require efficient image segmentation algorithms. Ultrasound videos often suffer from a low contrast level, shadow effects, and complex ‘noise’ statistics.
The research was published online in the April 7, 2016, issue of the SIAM Journal on Imaging Sciences and proposes a model for tracking moving boundaries in ultrasound video, using a mathematically sound framework. The model uses wavelet frames and noise statistics under a variational framework. The efficiency of the variational model makes it useful for real-time clinical applications. Such models are commonly used in motion tracking or edge detection, and have been shown to be robust and effective for complex image segmentation tasks. Wavelet frame regularization allowed the scientists to track and sharpen geometric shapes in the videos, while they were segmented automatically through sequential images. The model was designed to segment ultrasound videos sequentially and collectively, and to include shape priors during segmentation of a single image. Consecutive shape priors are then calculated automatically for subsequent segmentations.
Jiulong Liu, PhD student, Department of Mathematics, Shanghai Jiao Tong University (Shanghai, China), said, "Ultrasound imaging is an important modality in clinical application due to its low cost and portability. However, its related analysis for accurate diagnosis and monitoring is still challenging due to low image quality, artifacts, and noise. The numerical results on real ultrasound data sets demonstrate that the proposed wavelet frame model with distance prior can track the regions of interest effectively, in terms of both segmentation quality and computational time. The results compare favorably with other approaches. The model can be further extended to other imaging modality or to locate multi-region simultaneously. More geometric and prior information can be used to enhance the robustness of the method."
Related Links:
Shanghai Jiao Tong University
Real-time applications require efficient image segmentation algorithms. Ultrasound videos often suffer from a low contrast level, shadow effects, and complex ‘noise’ statistics.
The research was published online in the April 7, 2016, issue of the SIAM Journal on Imaging Sciences and proposes a model for tracking moving boundaries in ultrasound video, using a mathematically sound framework. The model uses wavelet frames and noise statistics under a variational framework. The efficiency of the variational model makes it useful for real-time clinical applications. Such models are commonly used in motion tracking or edge detection, and have been shown to be robust and effective for complex image segmentation tasks. Wavelet frame regularization allowed the scientists to track and sharpen geometric shapes in the videos, while they were segmented automatically through sequential images. The model was designed to segment ultrasound videos sequentially and collectively, and to include shape priors during segmentation of a single image. Consecutive shape priors are then calculated automatically for subsequent segmentations.
Jiulong Liu, PhD student, Department of Mathematics, Shanghai Jiao Tong University (Shanghai, China), said, "Ultrasound imaging is an important modality in clinical application due to its low cost and portability. However, its related analysis for accurate diagnosis and monitoring is still challenging due to low image quality, artifacts, and noise. The numerical results on real ultrasound data sets demonstrate that the proposed wavelet frame model with distance prior can track the regions of interest effectively, in terms of both segmentation quality and computational time. The results compare favorably with other approaches. The model can be further extended to other imaging modality or to locate multi-region simultaneously. More geometric and prior information can be used to enhance the robustness of the method."
Related Links:
Shanghai Jiao Tong University
Latest Ultrasound News
- Largest Model Trained On Echocardiography Images Assesses Heart Structure and Function
- Groundbreaking Technology Enables Precise, Automatic Measurement of Peripheral Blood Vessels
- Deep Learning Advances Super-Resolution Ultrasound Imaging
- Novel Ultrasound-Launched Targeted Nanoparticle Eliminates Biofilm and Bacterial Infection
- AI-Guided Ultrasound System Enables Rapid Assessments of DVT
- Focused Ultrasound Technique Gets Quality Assurance Protocol
- AI-Guided Handheld Ultrasound System Helps Capture Diagnostic-Quality Cardiac Images
- Non-Invasive Ultrasound Imaging Device Diagnoses Risk of Chronic Kidney Disease
- Wearable Ultrasound Platform Paves Way for 24/7 Blood Pressure Monitoring On the Wrist
- Diagnostic Ultrasound Enhancing Agent to Improve Image Quality in Pediatric Heart Patients
- AI Detects COVID-19 in Lung Ultrasound Images
- New Ultrasound Technology to Revolutionize Respiratory Disease Diagnoses
- Dynamic Contrast-Enhanced Ultrasound Highly Useful For Interventions
- Ultrasensitive Broadband Transparent Ultrasound Transducer Enhances Medical Diagnosis
- Artificial Intelligence Detects Heart Defects in Newborns from Ultrasound Images
- Ultrasound Imaging Technology Allows Doctors to Watch Spinal Cord Activity during Surgery