MedImaging

Download Mobile App
Recent News Radiography MRI Ultrasound Nuclear Medicine General/Advanced Imaging Imaging IT Industry News

X-ray Algorithm May Reduce Radiation Doses by Thousands-Fold

By MedImaging International staff writers
Posted on 21 Dec 2017
Print article
Image: A CT slice reconstruction of rabbit kitten lungs with absorption contrast CT at 0.16 m (a), Phase contrast CT at 2 m (b), and algorithm phase retrieval at 2 m (Photo courtesy of Monash University).
Image: A CT slice reconstruction of rabbit kitten lungs with absorption contrast CT at 0.16 m (a), Phase contrast CT at 2 m (b), and algorithm phase retrieval at 2 m (Photo courtesy of Monash University).
X-ray phase-contrast imaging (PCI) can improve the visibility of soft tissues by an order of magnitude or more compared to conventional radiographs, according to a new study.

Researchers at Monash University (Melbourne, Australia), the Japan Synchrotron Radiation Research Institute (JASRI; Sayo, Japan), and other institutions attempted to enhance image contrast by using phase shifts (refraction) of X-rays to increase signal-to-noise ratio (SNR) by up to two orders of magnitude--compared to conventional computerized tomography (CT) at the same radiation dose--and without loss of image quality. The results revealed that as radiation dose decreases, the relative improvement in SNR increases.

The researchers found that the enhancement can be traded for a reduction in dose greater than the square of the gain in SNR. Thus, reducing the dose by 300 fold resulted in the phase-retrieved SNR that was still almost 10 times larger than the absorption contrast data. According to the researchers, the potential for dose reduction factors in the tens of thousands without loss in image quality is possible, which would have a profound impact on medical and industrial imaging applications. The study was published on November 21, 2017, in Nature Scientific Reports.

“CT with high SNR and spatial resolution can potentially be achieved with less dose than a single projection-absorption based image. We therefore recommend using a large number of very low dose projections, coupled with phase retrieval before CT slice reconstruction,” concluded lead author Marcus Kitchen, PhD, of Monash University, and colleagues. “This will result in images with high SNR, retaining high spatial resolution, and minimizing any reconstruction artefacts due to insufficient CT projection angles.”

PCI is a general term for technical methods that use information concerning changes in the phase of an X-ray beam that passes through an object in order to create its images. While standard X-ray imaging techniques such as CT rely on a decrease of the beam's intensity, in PCI the x-ray beam's phase shift is not measured directly, but is transformed into variations in intensity, which then can be recorded. When applied to samples that consist of elements with low atomic numbers, PCI is more sensitive to density variations than conventional transmission-based X-ray imaging, which leads to improved soft tissue contrast.

Related Links:
Monash University
Japan Synchrotron Radiation Research Institute
Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
New
Remote Controlled Digital Radiography and Fluoroscopy System
Eco Track-DRF - MARS 50/MARS50+/MARS 65/MARS 80
New
Wireless Handheld Ultrasound System
TE Air
Brachytherapy Planning System
Oncentra Brachy

Print article

Channels

Ultrasound

view channel
Image: CAM figures of testing images (Photo courtesy of SPJ; DOI:10.34133/research.0319)

Diagnostic System Automatically Analyzes TTE Images to Identify Congenital Heart Disease

Congenital heart disease (CHD) is one of the most prevalent congenital anomalies worldwide, presenting substantial health and financial challenges for affected patients. Early detection and treatment of... Read more

Nuclear Medicine

view channel
Image: Whole-body maximum-intensity projections over time after [68Ga]Ga-DPI-4452 administration (Photo courtesy of SNMMI)

New PET Agent Rapidly and Accurately Visualizes Lesions in Clear Cell Renal Cell Carcinoma Patients

Clear cell renal cell cancer (ccRCC) represents 70-80% of renal cell carcinoma cases. While localized disease can be effectively treated with surgery and ablative therapies, one-third of patients either... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more