We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

MedImaging

Download Mobile App
Recent News Radiography MRI Ultrasound Nuclear Medicine General/Advanced Imaging Imaging IT Industry News

Miniature NMR Implant Measures Neuronal Activity

By MedImaging International staff writers
Posted on 17 Dec 2019
Print article
Image: The final functioning NMR probe mounted on a PCB holder (Photo courtesy of MPG)
Image: The final functioning NMR probe mounted on a PCB holder (Photo courtesy of MPG)
A highly sensitive nuclear magnetic resonance (NMR) implant probe enables brain physiology studies with enhanced spatial and temporal resolution.

Developed at the Max-Planck-Institute for Biological Cybernetics (MPG; Tübingen, Germany), the University of Tübingen (Germany), and the University of Stuttgart (Germany), the capillary monolithic probe combines an ultra-sensitive 300 µm coil with a complete NMR transceiver, enabling in vivo measurements of blood oxygenation and flow in nanoliter volumes at a sampling rate of 200 Hz. To minimize the risk of tissue damage during probe insertion, the multimodal probe possesses a needle-shape with shaft widths of 50-300 μm and shaft thicknesses below 100 μm.

The result is a complementary meta-oxide-semiconductor (CMOS) probe with the versatility of brain imaging technique that analyzes specific neuronal activity of the brain. According to the researchers, the design setup will allow scalable solutions by expanding the collection of data from more than a single area, but on the same device. The scalability will allow the use of other sensing modalities as well, such as electrophysiological, optogenetic, proton spectroscopy, and 31P spectroscopy measurements with high spatial resolution. The study was published on November 25, 2019 in Nature Methods.

“The integrated design of a nuclear magnetic resonance detector on a single chip supremely reduces the typical electromagnetic interference of magnetic resonance signals,” said senior author Klaus Scheffler, PhD, of the MPG department of high-field magnetic resonance. “This enables neuroscientists to gather precise data from minuscule areas of the brain, and to combine them with information from spatial and temporal data of the brain's physiology.”

The researchers suggest the system will allow the capture of localized activity within single layers, and preferably within regions of different cellular components, such as dendrites. In addition, it will allow the assessment of neurovascular coupling on a fine time scale, enabling extremely fast coupling that can help resolve correlations between electrical signals and proton magnetization changes, far below the commonly assumed time lag of several seconds.

Related Links:
Max-Planck-Institute for Biological Cybernetics
University of Tübingen
University of Stuttgart


New
Cylindrical Water Scanning System
SunSCAN 3D
Digital X-Ray Detector Panel
Acuity G4
Ultrasound Imaging System
P12 Elite
Multi-Use Ultrasound Table
Clinton

Print article

Channels

MRI

view channel
Image: The AI tool can help interpret and assess how well treatments are working for MS patients (Photo courtesy of Shutterstock)

AI Tool Tracks Effectiveness of Multiple Sclerosis Treatments Using Brain MRI Scans

Multiple sclerosis (MS) is a condition in which the immune system attacks the brain and spinal cord, leading to impairments in movement, sensation, and cognition. Magnetic Resonance Imaging (MRI) markers... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more