Head Circumference Determines Brain Damage in Newborns
By MedImaging International staff writers Posted on 19 Mar 2018 |

Image: A depression of the brain during birth due to large head circumference (Photo courtesy of Ruhr University).
A new cranial ultrasound study reveals that a large head circumference at birth increases the risk for brain damage by tenfold.
Researchers at Ruhr University (Bochum, Germany) and Wilhelmshaven Hospital (WHV; Germany) conducted a study that prospectively screened 4,725 term-born infants by cranial ultrasound in order to explore both the incidence and morphometric risk factors for white matter damage (WMD), an acknowledged prime risk factor for cerebral palsy (CP). The researchers related growth variables and risk factors of the term-born infants using odds ratios of z-score bands.
The results revealed that of the 61 term-born neonates identified with WMD, head circumference was a prime and unique index over the whole range of centiles, suggesting different mechanisms for WMD in the lowest and highest z-score band. While in the highest z-score band, cephalic pressure gradients and prolonged labor with preserved neonatal vitality prevailed, in the lowest band, acute and chronic oxygen deprivation with reduced vitality predominated. The study was published on February 28, 2018, in Obstetrics and Gynecology.
“The fact that seemingly healthy term-born neonates are not screened by head imaging, in spite of both large head circumference and prolonged labor, is considered to be the missing link between the insult that escapes diagnosis and the development of unexplained developmental delay and cerebral palsy in childhood,” said lead author Professor Arne Jensen, MD, of Ruhr-University. “Our findings may elucidate the phenomenon of unexplained cases of developmental delay and CP in the pediatric population on the basis of mechanical constraints and pressure gradients squeezing the skull and brain during parturition when a cephalopelvic disproportion is present.”
Cephalopelvic disproportion exists when the capacity of the pelvis is inadequate to allow the fetus to negotiate the birth canal. This may be due to a small pelvis, a nongynecoid pelvic formation, a large fetus, an unfavorable orientation of the fetus, or a combination of factors. From an evolutionary point of view, upright gait, a growing brain volume, and general growth acceleration will aggravate the problem and will lead to increased caesarean section rates in the highest z-score bands of head circumference in the future to prevent WMD.
Related Links:
Ruhr University
Wilhelmshaven Hospital
Researchers at Ruhr University (Bochum, Germany) and Wilhelmshaven Hospital (WHV; Germany) conducted a study that prospectively screened 4,725 term-born infants by cranial ultrasound in order to explore both the incidence and morphometric risk factors for white matter damage (WMD), an acknowledged prime risk factor for cerebral palsy (CP). The researchers related growth variables and risk factors of the term-born infants using odds ratios of z-score bands.
The results revealed that of the 61 term-born neonates identified with WMD, head circumference was a prime and unique index over the whole range of centiles, suggesting different mechanisms for WMD in the lowest and highest z-score band. While in the highest z-score band, cephalic pressure gradients and prolonged labor with preserved neonatal vitality prevailed, in the lowest band, acute and chronic oxygen deprivation with reduced vitality predominated. The study was published on February 28, 2018, in Obstetrics and Gynecology.
“The fact that seemingly healthy term-born neonates are not screened by head imaging, in spite of both large head circumference and prolonged labor, is considered to be the missing link between the insult that escapes diagnosis and the development of unexplained developmental delay and cerebral palsy in childhood,” said lead author Professor Arne Jensen, MD, of Ruhr-University. “Our findings may elucidate the phenomenon of unexplained cases of developmental delay and CP in the pediatric population on the basis of mechanical constraints and pressure gradients squeezing the skull and brain during parturition when a cephalopelvic disproportion is present.”
Cephalopelvic disproportion exists when the capacity of the pelvis is inadequate to allow the fetus to negotiate the birth canal. This may be due to a small pelvis, a nongynecoid pelvic formation, a large fetus, an unfavorable orientation of the fetus, or a combination of factors. From an evolutionary point of view, upright gait, a growing brain volume, and general growth acceleration will aggravate the problem and will lead to increased caesarean section rates in the highest z-score bands of head circumference in the future to prevent WMD.
Related Links:
Ruhr University
Wilhelmshaven Hospital
Latest Ultrasound News
- AI Identifies Heart Valve Disease from Common Imaging Test
- Novel Imaging Method Enables Early Diagnosis and Treatment Monitoring of Type 2 Diabetes
- Ultrasound-Based Microscopy Technique to Help Diagnose Small Vessel Diseases
- Smart Ultrasound-Activated Immune Cells Destroy Cancer Cells for Extended Periods
- Tiny Magnetic Robot Takes 3D Scans from Deep Within Body
- High Resolution Ultrasound Speeds Up Prostate Cancer Diagnosis
- World's First Wireless, Handheld, Whole-Body Ultrasound with Single PZT Transducer Makes Imaging More Accessible
- Artificial Intelligence Detects Undiagnosed Liver Disease from Echocardiograms
- Ultrasound Imaging Non-Invasively Tracks Tumor Response to Radiation and Immunotherapy
- AI Improves Detection of Congenital Heart Defects on Routine Prenatal Ultrasounds
- AI Diagnoses Lung Diseases from Ultrasound Videos with 96.57% Accuracy
- New Contrast Agent for Ultrasound Imaging Ensures Affordable and Safer Medical Diagnostics
- Ultrasound-Directed Microbubbles Boost Immune Response Against Tumors
- POC Ultrasound Enhances Early Pregnancy Care and Cuts Emergency Visits
- AI-Based Models Outperform Human Experts at Identifying Ovarian Cancer in Ultrasound Images
- Automated Breast Ultrasound Provides Alternative to Mammography in Low-Resource Settings
Channels
Radiography
view channel
World's Largest Class Single Crystal Diamond Radiation Detector Opens New Possibilities for Diagnostic Imaging
Diamonds possess ideal physical properties for radiation detection, such as exceptional thermal and chemical stability along with a quick response time. Made of carbon with an atomic number of six, diamonds... Read more
AI-Powered Imaging Technique Shows Promise in Evaluating Patients for PCI
Percutaneous coronary intervention (PCI), also known as coronary angioplasty, is a minimally invasive procedure where small metal tubes called stents are inserted into partially blocked coronary arteries... Read moreMRI
view channel
AI Tool Tracks Effectiveness of Multiple Sclerosis Treatments Using Brain MRI Scans
Multiple sclerosis (MS) is a condition in which the immune system attacks the brain and spinal cord, leading to impairments in movement, sensation, and cognition. Magnetic Resonance Imaging (MRI) markers... Read more
Ultra-Powerful MRI Scans Enable Life-Changing Surgery in Treatment-Resistant Epileptic Patients
Approximately 360,000 individuals in the UK suffer from focal epilepsy, a condition in which seizures spread from one part of the brain. Around a third of these patients experience persistent seizures... Read more
AI-Powered MRI Technology Improves Parkinson’s Diagnoses
Current research shows that the accuracy of diagnosing Parkinson’s disease typically ranges from 55% to 78% within the first five years of assessment. This is partly due to the similarities shared by Parkinson’s... Read more
Biparametric MRI Combined with AI Enhances Detection of Clinically Significant Prostate Cancer
Artificial intelligence (AI) technologies are transforming the way medical images are analyzed, offering unprecedented capabilities in quantitatively extracting features that go beyond traditional visual... Read moreNuclear Medicine
view channel
Novel PET Imaging Approach Offers Never-Before-Seen View of Neuroinflammation
COX-2, an enzyme that plays a key role in brain inflammation, can be significantly upregulated by inflammatory stimuli and neuroexcitation. Researchers suggest that COX-2 density in the brain could serve... Read more
Novel Radiotracer Identifies Biomarker for Triple-Negative Breast Cancer
Triple-negative breast cancer (TNBC), which represents 15-20% of all breast cancer cases, is one of the most aggressive subtypes, with a five-year survival rate of about 40%. Due to its significant heterogeneity... Read moreGeneral/Advanced Imaging
view channel
AI-Powered Imaging System Improves Lung Cancer Diagnosis
Given the need to detect lung cancer at earlier stages, there is an increasing need for a definitive diagnostic pathway for patients with suspicious pulmonary nodules. However, obtaining tissue samples... Read more
AI Model Significantly Enhances Low-Dose CT Capabilities
Lung cancer remains one of the most challenging diseases, making early diagnosis vital for effective treatment. Fortunately, advancements in artificial intelligence (AI) are revolutionizing lung cancer... Read moreImaging IT
view channel
New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible
Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Global AI in Medical Diagnostics Market to Be Driven by Demand for Image Recognition in Radiology
The global artificial intelligence (AI) in medical diagnostics market is expanding with early disease detection being one of its key applications and image recognition becoming a compelling consumer proposition... Read moreIndustry News
view channel
GE HealthCare and NVIDIA Collaboration to Reimagine Diagnostic Imaging
GE HealthCare (Chicago, IL, USA) has entered into a collaboration with NVIDIA (Santa Clara, CA, USA), expanding the existing relationship between the two companies to focus on pioneering innovation in... Read more
Patient-Specific 3D-Printed Phantoms Transform CT Imaging
New research has highlighted how anatomically precise, patient-specific 3D-printed phantoms are proving to be scalable, cost-effective, and efficient tools in the development of new CT scan algorithms... Read more
Siemens and Sectra Collaborate on Enhancing Radiology Workflows
Siemens Healthineers (Forchheim, Germany) and Sectra (Linköping, Sweden) have entered into a collaboration aimed at enhancing radiologists' diagnostic capabilities and, in turn, improving patient care... Read more