Coronary CTA Using DLR and Subtraction Technique Reduces Radiation Exposure, Improves Image Quality
By MedImaging International staff writers Posted on 12 Aug 2022 |
Coronary CTA with hybrid iterative reconstruction (HIR) is prone to false-positive results for in-stent restenosis due to stent-related blooming artifact. Now, a new study has found that the combination of deep-learning reconstruction (DLR) and a subtraction technique yielded optimal diagnostic performance for the detection of in-stent restenosis by coronary CTA.
The study was conducted by researchers at Peking Union Medical College Hospital (Beijing, China) to assess the impact of DLR, subtraction images, and combination of DLR and subtraction images on diagnostic performance of coronary CTA for detection of in-stent restenosis. Between March 2020 and August 2021, the research team studied 30 patients (22 men, 8 women; mean age, 63.6 years) with a total of 59 coronary stents who underwent coronary CTA using the two-breath-hold technique (i.e., non-contrast and contrast-enhanced acquisitions). Conventional and subtraction images were reconstructed for hybrid iterative reconstruction (HIR) and DLR, while maximum visible in-stent lumen diameter was measured. Two readers independently evaluated images for in-stent restenosis (≥50% stenosis). A simulated assessment of combined conventional and subtraction images was generated, reflecting assessment of conventional and subtraction images in the presence or absence of severe misregistration artifact, respectively. Invasive angiography served as reference standard.
The researchers found that ultimately, coronary CTA using DLR and subtraction technique - with a combined (conventional and subtraction images) interpretation - yielded PPV, NPV, and accuracy for in-stent restenosis for reader 1 of 73.3%, 93.2%, and 88.1%, and for reader 2 of 75.0%, 84.3%, and 83.1%, respectively. Noting that these findings could guide patient selection for invasive coronary stent evaluation, combining DLR with a two-breath-hold subtraction technique “may help overcome challenges related to stent-related blooming artifact,” according to corresponding author Yi-Ning Wang. Acknowledging that the two-breath-hold subtraction technique requires an additional non-contrast acquisition (and thus a higher radiation dose), “DLR allows a reduction in radiation exposure, while improving image quality,” wrote the authors.
Related Links:
Peking Union Medical College Hospital
Latest General/Advanced Imaging News
- Radiation Therapy Computed Tomography Solution Boosts Imaging Accuracy
- PET Scans Reveal Hidden Inflammation in Multiple Sclerosis Patients
- Artificial Intelligence Evaluates Cardiovascular Risk from CT Scans
- New AI Method Captures Uncertainty in Medical Images
- CT Coronary Angiography Reduces Need for Invasive Tests to Diagnose Coronary Artery Disease
- Novel Blood Test Could Reduce Need for PET Imaging of Patients with Alzheimer’s
- CT-Based Deep Learning Algorithm Accurately Differentiates Benign From Malignant Vertebral Fractures
- Minimally Invasive Procedure Could Help Patients Avoid Thyroid Surgery
- Self-Driving Mobile C-Arm Reduces Imaging Time during Surgery
- AR Application Turns Medical Scans Into Holograms for Assistance in Surgical Planning
- Imaging Technology Provides Ground-Breaking New Approach for Diagnosing and Treating Bowel Cancer
- CT Coronary Calcium Scoring Predicts Heart Attacks and Strokes
- AI Model Detects 90% of Lymphatic Cancer Cases from PET and CT Images
- Breakthrough Technology Revolutionizes Breast Imaging
- State-Of-The-Art System Enhances Accuracy of Image-Guided Diagnostic and Interventional Procedures
- Catheter-Based Device with New Cardiovascular Imaging Approach Offers Unprecedented View of Dangerous Plaques