Chest X-Rays Miss Most Blunt Trauma Injuries
By MedImaging International staff writers Posted on 15 Jul 2021 |
Image: Chest X-ray, the mainstay of trauma screening, misses many blunt injuries (Photo courtesy of Getty Images)
A new study suggests that when used alone, chest X-ray (CXR), without other trauma screening criteria, has poor screening performance for blunt thoracic injury.
For the study, researchers at the University of California, San Francisco (UCSF, USA) conducted a secondary analysis of data from the NEXUS Chest CT study (held between August 2011 and May 2014 at nine urban level-1 trauma centers in the United States), which included a total of 4,501 participants who had been injured primarily in motor vehicle accidents and who received initial chest x-rays, followed by computerized tomography (CT scans). The injuries were categorized as clinically major or minor.
The results revealed that CXR missed blunt trauma injuries in 818 patients (54.7%), of which 7.7% were classified as major injuries. The most common missed major injuries were sternal fractures, spinal fractures, and aortic injuries, while the most common missed minor injuries were pericardial effusions, sternal fractures, and mediastinal hematomas. The study was published on June 19, 2021, in the American Journal of Emergency Medicine.
“We do not suggest that the CXR should be completely abandoned in adult blunt trauma evaluation,” concluded study co-authors David Dillon, PhD, and Robert Rodriguez, MD. “The CXR is still useful for screening low risk trauma patients, and it is an essential component of our chest CT decision instrument, which safely guides selective chest CT utilization, with reductions of as many as 38% of chest CTs.”
CXR remains the main modality in screening and diagnosing thoracic injuries in trauma patients, used to visualize rib fractures, lung contusions, pneumothorax and hemothorax, emphysema, diaphragmatic and aortic injury, and fractures of the axial skeleton. It is common practice for a CXR taken in the emergency department to be assessed by the trauma team, and not by a trained radiologist.
Related Links:
University of California, San Francisco
For the study, researchers at the University of California, San Francisco (UCSF, USA) conducted a secondary analysis of data from the NEXUS Chest CT study (held between August 2011 and May 2014 at nine urban level-1 trauma centers in the United States), which included a total of 4,501 participants who had been injured primarily in motor vehicle accidents and who received initial chest x-rays, followed by computerized tomography (CT scans). The injuries were categorized as clinically major or minor.
The results revealed that CXR missed blunt trauma injuries in 818 patients (54.7%), of which 7.7% were classified as major injuries. The most common missed major injuries were sternal fractures, spinal fractures, and aortic injuries, while the most common missed minor injuries were pericardial effusions, sternal fractures, and mediastinal hematomas. The study was published on June 19, 2021, in the American Journal of Emergency Medicine.
“We do not suggest that the CXR should be completely abandoned in adult blunt trauma evaluation,” concluded study co-authors David Dillon, PhD, and Robert Rodriguez, MD. “The CXR is still useful for screening low risk trauma patients, and it is an essential component of our chest CT decision instrument, which safely guides selective chest CT utilization, with reductions of as many as 38% of chest CTs.”
CXR remains the main modality in screening and diagnosing thoracic injuries in trauma patients, used to visualize rib fractures, lung contusions, pneumothorax and hemothorax, emphysema, diaphragmatic and aortic injury, and fractures of the axial skeleton. It is common practice for a CXR taken in the emergency department to be assessed by the trauma team, and not by a trained radiologist.
Related Links:
University of California, San Francisco
Latest Radiography News
- Novel Breast Imaging System Proves As Effective As Mammography
- AI Assistance Improves Breast-Cancer Screening by Reducing False Positives
- AI Could Boost Clinical Adoption of Chest DDR
- 3D Mammography Almost Halves Breast Cancer Incidence between Two Screening Tests
- AI Model Predicts 5-Year Breast Cancer Risk from Mammograms
- Deep Learning Framework Detects Fractures in X-Ray Images With 99% Accuracy
- Direct AI-Based Medical X-Ray Imaging System a Paradigm-Shift from Conventional DR and CT
- Chest X-Ray AI Solution Automatically Identifies, Categorizes and Highlights Suspicious Areas
- AI Diagnoses Wrist Fractures As Well As Radiologists
- Annual Mammography Beginning At 40 Cuts Breast Cancer Mortality By 42%
- 3D Human GPS Powered By Light Paves Way for Radiation-Free Minimally-Invasive Surgery
- Novel AI Technology to Revolutionize Cancer Detection in Dense Breasts
- AI Solution Provides Radiologists with 'Second Pair' Of Eyes to Detect Breast Cancers
- AI Helps General Radiologists Achieve Specialist-Level Performance in Interpreting Mammograms
- Novel Imaging Technique Could Transform Breast Cancer Detection
- Computer Program Combines AI and Heat-Imaging Technology for Early Breast Cancer Detection