MR Imaging of COVID-19 Patients Should Be Avoided
By MedImaging International staff writers Posted on 06 May 2020 |
A new guidance statement by the American College of Radiology (ACR; Reston, VA, USA) recommends that radiologists avoid performing magnetic resonance imaging (MRI) exams on patients diagnosed with, or suspected of having, COVID-19.
The ACR guidance, issued on April 8, 2020, recommends that practitioners minimize the use of MRI except where absolutely necessary, and postpone all non-urgent or non-emergent exams. Prerequisites include implementation of site-specific cleaning and disinfecting protocols, including a 60 minute down-time between patients, to be followed by a cleaning protocol with approved cleaning agents that follow a clockwise, linear, top to bottom pattern on all visible surfaces. The ACR cleaning protocols need to be moderated by local policies, and especially the specific clinical needs of the patients and site, and can change over time.
In addition, MRI exams for patients should utilize standard surgical face masks or respirators (non-N95 respirators), that are known to be known MR Safe masks, prior to coming to the radiology department. Alternatively, when this is not possible, al metallic components from a face mask (such as a nose clip) should be removed prior to, or when necessary, upon the patient's arrival. Tape may be applied across the bridge of the nose section after removing the metal strip for fomite control and to maintain the mask’s intended function. If the patient has a tracheostomy, a face mask without metallic component should also be placed over the tracheostomy.
For staff and technologists, personal protective equipment (PPE) should be worn when entering a Zone IV area. The only safety concerns are potentially ferromagnetic components in the PPE (such as staples, metallic band inserts, etc.) and possible translational and rotational forces that the static magnetic field and the static magnetic field gradient may exert upon them. For such equipment, potential risks can be mitigated by such components and replacing them with tape. Powered air-purifying respirators (PAPR) should not be brought into Zone IV, due to the potential risks of adverse interactions with ferromagnetic components of the PAPR system.
Related Links:
American College of Radiology
The ACR guidance, issued on April 8, 2020, recommends that practitioners minimize the use of MRI except where absolutely necessary, and postpone all non-urgent or non-emergent exams. Prerequisites include implementation of site-specific cleaning and disinfecting protocols, including a 60 minute down-time between patients, to be followed by a cleaning protocol with approved cleaning agents that follow a clockwise, linear, top to bottom pattern on all visible surfaces. The ACR cleaning protocols need to be moderated by local policies, and especially the specific clinical needs of the patients and site, and can change over time.
In addition, MRI exams for patients should utilize standard surgical face masks or respirators (non-N95 respirators), that are known to be known MR Safe masks, prior to coming to the radiology department. Alternatively, when this is not possible, al metallic components from a face mask (such as a nose clip) should be removed prior to, or when necessary, upon the patient's arrival. Tape may be applied across the bridge of the nose section after removing the metal strip for fomite control and to maintain the mask’s intended function. If the patient has a tracheostomy, a face mask without metallic component should also be placed over the tracheostomy.
For staff and technologists, personal protective equipment (PPE) should be worn when entering a Zone IV area. The only safety concerns are potentially ferromagnetic components in the PPE (such as staples, metallic band inserts, etc.) and possible translational and rotational forces that the static magnetic field and the static magnetic field gradient may exert upon them. For such equipment, potential risks can be mitigated by such components and replacing them with tape. Powered air-purifying respirators (PAPR) should not be brought into Zone IV, due to the potential risks of adverse interactions with ferromagnetic components of the PAPR system.
Related Links:
American College of Radiology
Latest MRI News
- World's First Sensor Detects Errors in MRI Scans Using Laser Light and Gas
- Diamond Dust Could Offer New Contrast Agent Option for Future MRI Scans
- Combining MRI with PSA Testing Improves Clinical Outcomes for Prostate Cancer Patients
- PET/MRI Improves Diagnostic Accuracy for Prostate Cancer Patients
- Next Generation MR-Guided Focused Ultrasound Ushers In Future of Incisionless Neurosurgery
- Two-Part MRI Scan Detects Prostate Cancer More Quickly without Compromising Diagnostic Quality
- World’s Most Powerful MRI Machine Images Living Brain with Unrivaled Clarity
- New Whole-Body Imaging Technology Makes It Possible to View Inflammation on MRI Scan
- Combining Prostate MRI with Blood Test Can Avoid Unnecessary Prostate Biopsies
- New Treatment Combines MRI and Ultrasound to Control Prostate Cancer without Serious Side Effects
- MRI Improves Diagnosis and Treatment of Prostate Cancer
- Combined PET-MRI Scan Improves Treatment for Early Breast Cancer Patients
- 4D MRI Could Improve Clinical Assessment of Heart Blood Flow Abnormalities
- MRI-Guided Focused Ultrasound Therapy Shows Promise in Treating Prostate Cancer
- AI-Based MRI Tool Outperforms Current Brain Tumor Diagnosis Methods
- DW-MRI Lights up Small Ovarian Lesions like Light Bulbs