Compact Synchrotron Simplifies Coronary Angiography

By MedImaging International staff writers
Posted on 08 Mar 2017
Print article
Image: Dr. Munzel and a colleague near the MuCLS (Photo courtesy of TUM).
Image: Dr. Munzel and a colleague near the MuCLS (Photo courtesy of TUM).
An innovative miniature particle accelerator could significantly reduce the amount of contrast agents needed for coronary angiography by generating monoenergetic X-rays.

Developed by researchers at Munich Technical University and Klinikum rechts der Isar, the Munich Compact Light Source (MuCLS) mini-synchrotron can generate X-rays that have an exact monoenergetic optimal energy level. While this was previously possible only with circular particle accelerators with a diameter of several hundred meters, the MuCLS is a lot smaller, about the size of a car.

Contrast agents such as iodine and gadolinium have an energy absorption edge, which means that when the substance is exposed to X-rays of certain energy level, image contrast in the marked organ is very good. But when energy levels are below the absorption edge (30 keV for iodine), contrast deteriorates rapidly. The contrast also becomes weaker at energies far above the absorption edge. Consequently, conventional broad-spectrum X-ray sources require an adequate quantity of contrast agent in order to offset this effect and obtain a sufficiently sharp image for diagnosis.

According to the researchers, using monoenergetic X-rays would make it possible to decrease the required concentration of contrast agents significantly. Iodine levels could be reduced by about one third with no loss of contrast, while for gadolinium the reduction could even greater, around 50%. The researchers added that the experimental approach can be extended in the future to dual-energy K-edge subtraction angiography, where the beam energy is oscillated rapidly between above and below the energy absorption edge. The study was published on February 9, 2017, in Nature Scientific Reports.

“Conventional X-ray sources generate a relatively broad range of energy levels. By contrast, the energy of X-rays produced by the MuCLS can be controlled much more precisely,” said lead author physicist Elena Eggl, PhD, of TUM. “The MuCLS is the very first machine of its kind; moreover, it is designed for fundamental research, and not for examining patients. But with detailed computer simulations and tests with a pig's heart, using blood vessels dyed with iodine, [we] were able to demonstrate feasibility of the method.”

“Soft tissues such as organs and blood vessels are nearly impossible to examine in X-ray images; to detect a narrowing or other changes in coronary blood vessels, patients are therefore usually injected with an iodinated contrast agent,” said senior author Daniela Münzel, MD, an adjunct teaching professor for radiology at Klinikum rechts der Isar. “These substances can sometimes be hazardous to health, particularly in patients with kidney insufficiency; complications may arise, in some cases even kidney failure.”

Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
New
Remote Controlled Digital Radiography and Fluoroscopy System
Eco Track-DRF - MARS 50/MARS50+/MARS 65/MARS 80
New
Ultrasound Table
Powered Ultrasound Table-Flat Top
New
Wireless Handheld Ultrasound System
TE Air

Print article

Channels

Ultrasound

view channel
Image: CAM figures of testing images (Photo courtesy of SPJ; DOI:10.34133/research.0319)

Diagnostic System Automatically Analyzes TTE Images to Identify Congenital Heart Disease

Congenital heart disease (CHD) is one of the most prevalent congenital anomalies worldwide, presenting substantial health and financial challenges for affected patients. Early detection and treatment of... Read more

Nuclear Medicine

view channel
Image: Whole-body maximum-intensity projections over time after [68Ga]Ga-DPI-4452 administration (Photo courtesy of SNMMI)

New PET Agent Rapidly and Accurately Visualizes Lesions in Clear Cell Renal Cell Carcinoma Patients

Clear cell renal cell cancer (ccRCC) represents 70-80% of renal cell carcinoma cases. While localized disease can be effectively treated with surgery and ablative therapies, one-third of patients either... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more