We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

MedImaging

Download Mobile App
Recent News Radiography MRI Ultrasound Nuclear Medicine General/Advanced Imaging Imaging IT Industry News

Tomosynthesis Application More Sensitive Than Chest X-Ray Detecting Lung Nodules

By MedImaging International staff writers
Posted on 16 Jan 2014
Print article
Image: VolumeRAD offers improved detection and management of patients with lung nodules compared to conventional X-ray imaging of the chest (Photo courtesy of GE Healthcare).
Image: VolumeRAD offers improved detection and management of patients with lung nodules compared to conventional X-ray imaging of the chest (Photo courtesy of GE Healthcare).
A new tomosynthesis tool provides enhanced detection and management of lung cancer patients and is 7.5 times more sensitive than chest X-ray without decreased specificity in identifying patients who require follow-up.

GE Healthcare’s (Chalfont St. Giles, UK) new clinical application for its fixed radiographic system, VolumeRAD, offers improved detection and management of patients with lung nodules compared to conventional X-ray imaging of the chest. As the first thoracic radiographic tomosynthesis product with a specific indication, this application is designed to improve the detection of lung nodules and the subsequent management of patients.

VolumeRAD provides physicians with multiple high-resolution slice images of the anatomy of interest, including the chest, abdomen, extremities, and spine. This clinical feature is a method of acquiring a series of low-dose projection images during a single sweep of the X-ray tube over a limited angle.

“We are very excited by these results that clearly show the benefit of radiographic tomosynthesis vs conventional X-ray,” said Michelle Edler, general manager of radiology and fluoroscopy for GE’s detection and guidance solutions business. “Customers who use this technology will be able to detect more, and will benefit 360% greater sensitivity without any reduction in specificity, for lung nodules 3–20 mm in diameter. The potential of VolumeRAD as a high-quality, cost-effective, and low dose imaging alternative for lung nodule detection is massive.”

Dr Gautham Reddy, professor of radiology and vice chair for education and director of thoracic imaging in the department of radiology at the University of Washington (Seattle, USA) believes VolumeRAD can offer an intermediate solution for patient care. “Rather than simply getting a CT, we can do a VolumeRAD to verify whether it’s a nodule or not. [For] something that has low likelihood of being a nodule, VolumeRAD will probably exclude the possibility of a nodule and there won’t be as much radiation,” said Dr. Reddy. “That is one of the reasons why VolumeRAD would be helpful. We could get more information than with a [radiograph and] without as much radiation as a CT.”

VolumeRAD generates diagnostic chest images that enable radiologists to detect small lung nodules with superior sensitivity vs. posterior-anterior (PA) and left lateral views of the chest at minimal relative radiation level (< 0.1 mSv). This clinical feature is a way of acquiring a series of low-dose projection images during a single sweep of the X-ray tube over a limited angle.

As many as 60 images can be captured in approximately 10 seconds. These data are then used to generate images at the desired slice interval defined by the user, a huge dose and patient throughput benefit compared to linear tomography, which provides only one image from a similar tube sweep. Using CT-like algorithms, high-resolution thin slices are reconstructed and can be reviewed by the radiologist at a computer workstation as individual images or in a cine mode.

Related Links:

GE Healthcare


Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
New
Pre-Op Planning Solution
Sectra 3D Trauma
Thyroid Shield
Standard Thyroid Shield
New
CT Phantom
CIRS Model 610 AAPM CT Performance Phantom

Print article
Radcal

Channels

MRI

view channel
Image: Diamond dust offers a potential alternative to the widely used contrast agent gadolinium in MRI (Photo courtesy of Max Planck Institute)

Diamond Dust Could Offer New Contrast Agent Option for Future MRI Scans

Gadolinium, a heavy metal used for over three decades as a contrast agent in medical imaging, enhances the clarity of MRI scans by highlighting affected areas. Despite its utility, gadolinium not only... Read more

Nuclear Medicine

view channel
Image: The new SPECT/CT technique demonstrated impressive biomarker identification (Journal of Nuclear Medicine: doi.org/10.2967/jnumed.123.267189)

New SPECT/CT Technique Could Change Imaging Practices and Increase Patient Access

The development of lead-212 (212Pb)-PSMA–based targeted alpha therapy (TAT) is garnering significant interest in treating patients with metastatic castration-resistant prostate cancer. The imaging of 212Pb,... Read more

Imaging IT

view channel
Image: The new Medical Imaging Suite makes healthcare imaging data more accessible, interoperable and useful (Photo courtesy of Google Cloud)

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more