MR Imaging of COVID-19 Patients Should Be Avoided
By MedImaging International staff writers Posted on 06 May 2020 |
A new guidance statement by the American College of Radiology (ACR; Reston, VA, USA) recommends that radiologists avoid performing magnetic resonance imaging (MRI) exams on patients diagnosed with, or suspected of having, COVID-19.
The ACR guidance, issued on April 8, 2020, recommends that practitioners minimize the use of MRI except where absolutely necessary, and postpone all non-urgent or non-emergent exams. Prerequisites include implementation of site-specific cleaning and disinfecting protocols, including a 60 minute down-time between patients, to be followed by a cleaning protocol with approved cleaning agents that follow a clockwise, linear, top to bottom pattern on all visible surfaces. The ACR cleaning protocols need to be moderated by local policies, and especially the specific clinical needs of the patients and site, and can change over time.
In addition, MRI exams for patients should utilize standard surgical face masks or respirators (non-N95 respirators), that are known to be known MR Safe masks, prior to coming to the radiology department. Alternatively, when this is not possible, al metallic components from a face mask (such as a nose clip) should be removed prior to, or when necessary, upon the patient's arrival. Tape may be applied across the bridge of the nose section after removing the metal strip for fomite control and to maintain the mask’s intended function. If the patient has a tracheostomy, a face mask without metallic component should also be placed over the tracheostomy.
For staff and technologists, personal protective equipment (PPE) should be worn when entering a Zone IV area. The only safety concerns are potentially ferromagnetic components in the PPE (such as staples, metallic band inserts, etc.) and possible translational and rotational forces that the static magnetic field and the static magnetic field gradient may exert upon them. For such equipment, potential risks can be mitigated by such components and replacing them with tape. Powered air-purifying respirators (PAPR) should not be brought into Zone IV, due to the potential risks of adverse interactions with ferromagnetic components of the PAPR system.
Related Links:
American College of Radiology
The ACR guidance, issued on April 8, 2020, recommends that practitioners minimize the use of MRI except where absolutely necessary, and postpone all non-urgent or non-emergent exams. Prerequisites include implementation of site-specific cleaning and disinfecting protocols, including a 60 minute down-time between patients, to be followed by a cleaning protocol with approved cleaning agents that follow a clockwise, linear, top to bottom pattern on all visible surfaces. The ACR cleaning protocols need to be moderated by local policies, and especially the specific clinical needs of the patients and site, and can change over time.
In addition, MRI exams for patients should utilize standard surgical face masks or respirators (non-N95 respirators), that are known to be known MR Safe masks, prior to coming to the radiology department. Alternatively, when this is not possible, al metallic components from a face mask (such as a nose clip) should be removed prior to, or when necessary, upon the patient's arrival. Tape may be applied across the bridge of the nose section after removing the metal strip for fomite control and to maintain the mask’s intended function. If the patient has a tracheostomy, a face mask without metallic component should also be placed over the tracheostomy.
For staff and technologists, personal protective equipment (PPE) should be worn when entering a Zone IV area. The only safety concerns are potentially ferromagnetic components in the PPE (such as staples, metallic band inserts, etc.) and possible translational and rotational forces that the static magnetic field and the static magnetic field gradient may exert upon them. For such equipment, potential risks can be mitigated by such components and replacing them with tape. Powered air-purifying respirators (PAPR) should not be brought into Zone IV, due to the potential risks of adverse interactions with ferromagnetic components of the PAPR system.
Related Links:
American College of Radiology
Latest MRI News
- AI Tool Tracks Effectiveness of Multiple Sclerosis Treatments Using Brain MRI Scans
- Ultra-Powerful MRI Scans Enable Life-Changing Surgery in Treatment-Resistant Epileptic Patients
- AI-Powered MRI Technology Improves Parkinson’s Diagnoses
- Biparametric MRI Combined with AI Enhances Detection of Clinically Significant Prostate Cancer
- First-Of-Its-Kind AI-Driven Brain Imaging Platform to Better Guide Stroke Treatment Options
- New Model Improves Comparison of MRIs Taken at Different Institutions
- Groundbreaking New Scanner Sees 'Previously Undetectable' Cancer Spread
- First-Of-Its-Kind Tool Analyzes MRI Scans to Measure Brain Aging
- AI-Enhanced MRI Images Make Cancerous Breast Tissue Glow
- AI Model Automatically Segments MRI Images
- New Research Supports Routine Brain MRI Screening in Asymptomatic Late-Stage Breast Cancer Patients
- Revolutionary Portable Device Performs Rapid MRI-Based Stroke Imaging at Patient's Bedside
- AI Predicts After-Effects of Brain Tumor Surgery from MRI Scans
- MRI-First Strategy for Prostate Cancer Detection Proven Safe
- First-Of-Its-Kind 10' x 48' Mobile MRI Scanner Transforms User and Patient Experience
- New Model Makes MRI More Accurate and Reliable
Channels
Radiography
view channel
World's Largest Class Single Crystal Diamond Radiation Detector Opens New Possibilities for Diagnostic Imaging
Diamonds possess ideal physical properties for radiation detection, such as exceptional thermal and chemical stability along with a quick response time. Made of carbon with an atomic number of six, diamonds... Read more
AI-Powered Imaging Technique Shows Promise in Evaluating Patients for PCI
Percutaneous coronary intervention (PCI), also known as coronary angioplasty, is a minimally invasive procedure where small metal tubes called stents are inserted into partially blocked coronary arteries... Read moreUltrasound
view channel
AI Identifies Heart Valve Disease from Common Imaging Test
Tricuspid regurgitation is a condition where the heart's tricuspid valve does not close completely during contraction, leading to backward blood flow, which can result in heart failure. A new artificial... Read more
Novel Imaging Method Enables Early Diagnosis and Treatment Monitoring of Type 2 Diabetes
Type 2 diabetes is recognized as an autoimmune inflammatory disease, where chronic inflammation leads to alterations in pancreatic islet microvasculature, a key factor in β-cell dysfunction.... Read moreNuclear Medicine
view channel
Novel PET Imaging Approach Offers Never-Before-Seen View of Neuroinflammation
COX-2, an enzyme that plays a key role in brain inflammation, can be significantly upregulated by inflammatory stimuli and neuroexcitation. Researchers suggest that COX-2 density in the brain could serve... Read more
Novel Radiotracer Identifies Biomarker for Triple-Negative Breast Cancer
Triple-negative breast cancer (TNBC), which represents 15-20% of all breast cancer cases, is one of the most aggressive subtypes, with a five-year survival rate of about 40%. Due to its significant heterogeneity... Read moreGeneral/Advanced Imaging
view channel
AI-Powered Imaging System Improves Lung Cancer Diagnosis
Given the need to detect lung cancer at earlier stages, there is an increasing need for a definitive diagnostic pathway for patients with suspicious pulmonary nodules. However, obtaining tissue samples... Read more
AI Model Significantly Enhances Low-Dose CT Capabilities
Lung cancer remains one of the most challenging diseases, making early diagnosis vital for effective treatment. Fortunately, advancements in artificial intelligence (AI) are revolutionizing lung cancer... Read moreImaging IT
view channel
New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible
Medical imaging is a critical tool used to diagnose patients, and there are billions of medical images scanned globally each year. Imaging data accounts for about 90% of all healthcare data1 and, until... Read more
Global AI in Medical Diagnostics Market to Be Driven by Demand for Image Recognition in Radiology
The global artificial intelligence (AI) in medical diagnostics market is expanding with early disease detection being one of its key applications and image recognition becoming a compelling consumer proposition... Read moreIndustry News
view channel
GE HealthCare and NVIDIA Collaboration to Reimagine Diagnostic Imaging
GE HealthCare (Chicago, IL, USA) has entered into a collaboration with NVIDIA (Santa Clara, CA, USA), expanding the existing relationship between the two companies to focus on pioneering innovation in... Read more
Patient-Specific 3D-Printed Phantoms Transform CT Imaging
New research has highlighted how anatomically precise, patient-specific 3D-printed phantoms are proving to be scalable, cost-effective, and efficient tools in the development of new CT scan algorithms... Read more
Siemens and Sectra Collaborate on Enhancing Radiology Workflows
Siemens Healthineers (Forchheim, Germany) and Sectra (Linköping, Sweden) have entered into a collaboration aimed at enhancing radiologists' diagnostic capabilities and, in turn, improving patient care... Read more