Fiber-Based Endoscopy Enables Deep-Brain Imaging
By MedImaging International staff writers Posted on 24 Dec 2018 |
Image: Neuronal somata, neuronal processes, and time-lapse images of a hemorrhage in the primary visual cortex (Photo courtesy of IPTH).
A real-time fluorescent imaging probe captures neuronal dynamics in deep-brain layers at a resolution of around one micron, according to a new study.
Developed by researchers at the Leibniz Institute of Photonic Technology (IPTH; Germany) and the University of Edinburgh (United Kingdom), the multimode fiber (MMF) endoscopic probe provides a compact, ultranarrow, high-speed system for fluorescent imaging that can achieve an average resolution of 1.18 µm across a 50-µm field of view, resulting in 7-kilopixel images at a rate of 3.5 frames per second. The hair-thin probe also overcomes the limitations on size inside living tissues, leaving no structural and functional impact.
The compact, high-speed imaging system was used to resolve micron-sized subcellular neural structures in an anaesthetized mouse model involving 5 mice. The reduced footprint of the imaging probe allowed observations of structures deep within various brain tissues, including in vivo resolution of neuronal connectivity in previously inaccessible structures, such as the visual cortex and the hippocampus. The researchers suggest that the technique will help explore many knowledge gaps, such as those regarding memory formation and sensory perception. The study was published on November 21, 2018, in Light: Science and Applications.
“We have designed a highly optimized optical pathway for fluorescence-based imaging of deep brain structures with micrometric spatial resolution, while causing minimal damage to the tissue surrounding the fiber penetration area,” concluded senior author Tomáš Čižmár, PhD, of IPTH, and colleagues. “Deploying the most efficient wavefront-shaping algorithms and, currently, the fastest possible hardware for light modulation, this provides adequate spatial and temporal resolution for fluorescent imaging of subcellular structures in living tissues. The robust design allows continuous imaging for periods of several hours.”
Digital micromirror devices (DMDs) have recently opened up a whole new range of opportunities in the field of holographic control of light propagation in complex media by increasing light modulation refresh rates by several orders of magnitude. As a result, the foci behind a MMF can now be scanned at several tens of kHz, acquiring images at speeds approaching video rates. In addition, single fiber-based imaging not only shortens the post-operative recovery period but also eliminates the need to implant optical imaging elements.
Related Links:
Leibniz Institute of Photonic Technology
University of Edinburgh
Developed by researchers at the Leibniz Institute of Photonic Technology (IPTH; Germany) and the University of Edinburgh (United Kingdom), the multimode fiber (MMF) endoscopic probe provides a compact, ultranarrow, high-speed system for fluorescent imaging that can achieve an average resolution of 1.18 µm across a 50-µm field of view, resulting in 7-kilopixel images at a rate of 3.5 frames per second. The hair-thin probe also overcomes the limitations on size inside living tissues, leaving no structural and functional impact.
The compact, high-speed imaging system was used to resolve micron-sized subcellular neural structures in an anaesthetized mouse model involving 5 mice. The reduced footprint of the imaging probe allowed observations of structures deep within various brain tissues, including in vivo resolution of neuronal connectivity in previously inaccessible structures, such as the visual cortex and the hippocampus. The researchers suggest that the technique will help explore many knowledge gaps, such as those regarding memory formation and sensory perception. The study was published on November 21, 2018, in Light: Science and Applications.
“We have designed a highly optimized optical pathway for fluorescence-based imaging of deep brain structures with micrometric spatial resolution, while causing minimal damage to the tissue surrounding the fiber penetration area,” concluded senior author Tomáš Čižmár, PhD, of IPTH, and colleagues. “Deploying the most efficient wavefront-shaping algorithms and, currently, the fastest possible hardware for light modulation, this provides adequate spatial and temporal resolution for fluorescent imaging of subcellular structures in living tissues. The robust design allows continuous imaging for periods of several hours.”
Digital micromirror devices (DMDs) have recently opened up a whole new range of opportunities in the field of holographic control of light propagation in complex media by increasing light modulation refresh rates by several orders of magnitude. As a result, the foci behind a MMF can now be scanned at several tens of kHz, acquiring images at speeds approaching video rates. In addition, single fiber-based imaging not only shortens the post-operative recovery period but also eliminates the need to implant optical imaging elements.
Related Links:
Leibniz Institute of Photonic Technology
University of Edinburgh
Latest General/Advanced Imaging News
- Artificial Intelligence Evaluates Cardiovascular Risk from CT Scans
- New AI Method Captures Uncertainty in Medical Images
- CT Coronary Angiography Reduces Need for Invasive Tests to Diagnose Coronary Artery Disease
- Novel Blood Test Could Reduce Need for PET Imaging of Patients with Alzheimer’s
- CT-Based Deep Learning Algorithm Accurately Differentiates Benign From Malignant Vertebral Fractures
- Minimally Invasive Procedure Could Help Patients Avoid Thyroid Surgery
- Self-Driving Mobile C-Arm Reduces Imaging Time during Surgery
- AR Application Turns Medical Scans Into Holograms for Assistance in Surgical Planning
- Imaging Technology Provides Ground-Breaking New Approach for Diagnosing and Treating Bowel Cancer
- CT Coronary Calcium Scoring Predicts Heart Attacks and Strokes
- AI Model Detects 90% of Lymphatic Cancer Cases from PET and CT Images
- Breakthrough Technology Revolutionizes Breast Imaging
- State-Of-The-Art System Enhances Accuracy of Image-Guided Diagnostic and Interventional Procedures
- Catheter-Based Device with New Cardiovascular Imaging Approach Offers Unprecedented View of Dangerous Plaques
- AI Model Draws Maps to Accurately Identify Tumors and Diseases in Medical Images
- AI-Enabled CT System Provides More Accurate and Reliable Imaging Results