Laser-Sonic Scanner Images Entire Breast in Seconds
By MedImaging International staff writers Posted on 25 Jun 2018 |
Image: The internal vascular structure of a human breast created using a PACT scanner (Photo courtesy of Caltech).
A new study describes how a photoacoustic computed tomography (PACT) scanning system can find breast tumors faster than mammography.
Developed by researchers at Washington University School of Medicine (WUSTL; St. Louis, MO, USA), the California Institute of Technology (Caltech; Pasadena, USA), and other institutions, PACT involves shining a near-infrared (NIR) laser pulse that diffuses through the breast and is absorbed by oxygen-carrying hemoglobin molecules in the patient's red blood cells (RBCs), causing the molecules to vibrate ultrasonically. The vibrations travel through the tissue and are picked up by an array of 512 tiny ultrasonic sensors around the skin of the breast.
The data from the sensors are used to assemble an image of the breast's internal structures in a process that is similar to ultrasound imaging, though much more precise. Because the laser light is so strongly absorbed by hemoglobin, PACT can construct images that primarily show the blood vessels present in the tissue being scanned, providing a clear view of structures as small as a quarter of a millimeter at a depth of four centimeters.
Since the scan is quick, taking only 15 seconds, the patient can easily hold their breath while being scanned, and a clearer image can be developed. According to the researchers, the speed with which a PACT scan can be performed gives it advantages over other imaging techniques. For example, magnetic resonance imaging (MRI) scans can take 45 minutes, are expensive, and sometimes requires contrast agents to be injected into the patient's blood. The study was published on June 15, 2018, in Nature Communications.
“Mammograms cannot provide soft-tissue contrast with the level of detail in PACT images. This is the only single-breath-hold technology that gives us high-contrast, high-resolution, 3-D images of the entire breast,” said senior author professor of medical and electrical engineering Lihong Wang, PhD, of WUSTL. “Our goal is to build a dream machine for breast screening, diagnosis, monitoring, and prognosis without any harm to the patient. We want it to be fast, painless, safe, and inexpensive.”
PACT offers high spatial and temporal resolutions with sufficiently deep nonionizing optical penetration, since the principal optical absorber in the NIR region, hemoglobin, provides an endogenous contrast for imaging a high density of blood vessels. The concentration of blood vessels is often associated with angiogenesis, which plays an important role in tumor growth and metastasis.
Related Links:
Washington University School of Medicine
California Institute of Technology
Developed by researchers at Washington University School of Medicine (WUSTL; St. Louis, MO, USA), the California Institute of Technology (Caltech; Pasadena, USA), and other institutions, PACT involves shining a near-infrared (NIR) laser pulse that diffuses through the breast and is absorbed by oxygen-carrying hemoglobin molecules in the patient's red blood cells (RBCs), causing the molecules to vibrate ultrasonically. The vibrations travel through the tissue and are picked up by an array of 512 tiny ultrasonic sensors around the skin of the breast.
The data from the sensors are used to assemble an image of the breast's internal structures in a process that is similar to ultrasound imaging, though much more precise. Because the laser light is so strongly absorbed by hemoglobin, PACT can construct images that primarily show the blood vessels present in the tissue being scanned, providing a clear view of structures as small as a quarter of a millimeter at a depth of four centimeters.
Since the scan is quick, taking only 15 seconds, the patient can easily hold their breath while being scanned, and a clearer image can be developed. According to the researchers, the speed with which a PACT scan can be performed gives it advantages over other imaging techniques. For example, magnetic resonance imaging (MRI) scans can take 45 minutes, are expensive, and sometimes requires contrast agents to be injected into the patient's blood. The study was published on June 15, 2018, in Nature Communications.
“Mammograms cannot provide soft-tissue contrast with the level of detail in PACT images. This is the only single-breath-hold technology that gives us high-contrast, high-resolution, 3-D images of the entire breast,” said senior author professor of medical and electrical engineering Lihong Wang, PhD, of WUSTL. “Our goal is to build a dream machine for breast screening, diagnosis, monitoring, and prognosis without any harm to the patient. We want it to be fast, painless, safe, and inexpensive.”
PACT offers high spatial and temporal resolutions with sufficiently deep nonionizing optical penetration, since the principal optical absorber in the NIR region, hemoglobin, provides an endogenous contrast for imaging a high density of blood vessels. The concentration of blood vessels is often associated with angiogenesis, which plays an important role in tumor growth and metastasis.
Related Links:
Washington University School of Medicine
California Institute of Technology
Latest General/Advanced Imaging News
- PET Scans Reveal Hidden Inflammation in Multiple Sclerosis Patients
- Artificial Intelligence Evaluates Cardiovascular Risk from CT Scans
- New AI Method Captures Uncertainty in Medical Images
- CT Coronary Angiography Reduces Need for Invasive Tests to Diagnose Coronary Artery Disease
- Novel Blood Test Could Reduce Need for PET Imaging of Patients with Alzheimer’s
- CT-Based Deep Learning Algorithm Accurately Differentiates Benign From Malignant Vertebral Fractures
- Minimally Invasive Procedure Could Help Patients Avoid Thyroid Surgery
- Self-Driving Mobile C-Arm Reduces Imaging Time during Surgery
- AR Application Turns Medical Scans Into Holograms for Assistance in Surgical Planning
- Imaging Technology Provides Ground-Breaking New Approach for Diagnosing and Treating Bowel Cancer
- CT Coronary Calcium Scoring Predicts Heart Attacks and Strokes
- AI Model Detects 90% of Lymphatic Cancer Cases from PET and CT Images
- Breakthrough Technology Revolutionizes Breast Imaging
- State-Of-The-Art System Enhances Accuracy of Image-Guided Diagnostic and Interventional Procedures
- Catheter-Based Device with New Cardiovascular Imaging Approach Offers Unprecedented View of Dangerous Plaques
- AI Model Draws Maps to Accurately Identify Tumors and Diseases in Medical Images