Brain Mapping Tool Identifies Diseased Tissue
By MedImaging International staff writers Posted on 07 Jun 2017 |
Image: The PEDOT:PSS electrode grid (Photo courtesy of David Baillot / UCSD).
A new device to map the brain during surgery provides higher resolution neural readings than existing tools used in the clinic and could enable doctors to perform safer, more precise brain surgeries.
Developed by researchers at the University of California, San Diego (UCSD, USA), Massachusetts General Hospital (MGH; Boston, USA), and other institutions, the device is an improved version of an electrocorticography electrode grid, which takes advantage of the electrochemical properties of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). Using PEDOT:PSS allows the new electrode grid to be about a thousand times thinner than current clinical electrode grids.
The PEDOT:PSS microelectrode arrays is just 6 micrometers thick (versus several millimeters in current grids), which allows it to conform better to the intricately curved surface of the brain and obtain better readings. The new electrode grid also contains a much higher density of electrodes, since they can be spaced 25 times closer than those in current clinical electrode grids, enabling detection of changes in amplitude across pial surface distances as small as 400 µm, resulting in higher resolution recordings. The researchers also conducted several clinical tests.
In one test, the researchers performed background readings of a patient's brain waves both awake and unconscious. The PEDOT:PSS electrode grid identified normal functioning areas of the brain versus where the seizure areas with more detailed and higher resolution readings than the clinical electrode grid. Other tests that monitored the brain activity of patients performing cognitive tasks showed that both the PEDOT:PSS and standard electrode grids could differentiate between visual and audio inputs. The study was published on May 12, 2017, in Advanced Functional Materials.
“By providing higher resolution views of the human brain, this technology can improve clinical practices and could lead to high performance brain machine interfaces,” said senior author Professor Vikash Gilja, PhD, of the department of engineering at UC San Diego. “These electrodes occupy minuscule volumes; imagine Saran Wrap, but thinner. And we demonstrate that they can capture neural activity from the human brain at least as well as conventional electrodes that are orders of magnitude larger.”
Related Links:
University of California, San Diego
Massachusetts General Hospital
Developed by researchers at the University of California, San Diego (UCSD, USA), Massachusetts General Hospital (MGH; Boston, USA), and other institutions, the device is an improved version of an electrocorticography electrode grid, which takes advantage of the electrochemical properties of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS). Using PEDOT:PSS allows the new electrode grid to be about a thousand times thinner than current clinical electrode grids.
The PEDOT:PSS microelectrode arrays is just 6 micrometers thick (versus several millimeters in current grids), which allows it to conform better to the intricately curved surface of the brain and obtain better readings. The new electrode grid also contains a much higher density of electrodes, since they can be spaced 25 times closer than those in current clinical electrode grids, enabling detection of changes in amplitude across pial surface distances as small as 400 µm, resulting in higher resolution recordings. The researchers also conducted several clinical tests.
In one test, the researchers performed background readings of a patient's brain waves both awake and unconscious. The PEDOT:PSS electrode grid identified normal functioning areas of the brain versus where the seizure areas with more detailed and higher resolution readings than the clinical electrode grid. Other tests that monitored the brain activity of patients performing cognitive tasks showed that both the PEDOT:PSS and standard electrode grids could differentiate between visual and audio inputs. The study was published on May 12, 2017, in Advanced Functional Materials.
“By providing higher resolution views of the human brain, this technology can improve clinical practices and could lead to high performance brain machine interfaces,” said senior author Professor Vikash Gilja, PhD, of the department of engineering at UC San Diego. “These electrodes occupy minuscule volumes; imagine Saran Wrap, but thinner. And we demonstrate that they can capture neural activity from the human brain at least as well as conventional electrodes that are orders of magnitude larger.”
Related Links:
University of California, San Diego
Massachusetts General Hospital
Latest General/Advanced Imaging News
- Bone Density Test Uses Existing CT Images to Predict Fractures
- AI Predicts Cardiac Risk and Mortality from Routine Chest CT Scans
- Radiation Therapy Computed Tomography Solution Boosts Imaging Accuracy
- PET Scans Reveal Hidden Inflammation in Multiple Sclerosis Patients
- Artificial Intelligence Evaluates Cardiovascular Risk from CT Scans
- New AI Method Captures Uncertainty in Medical Images
- CT Coronary Angiography Reduces Need for Invasive Tests to Diagnose Coronary Artery Disease
- Novel Blood Test Could Reduce Need for PET Imaging of Patients with Alzheimer’s
- CT-Based Deep Learning Algorithm Accurately Differentiates Benign From Malignant Vertebral Fractures
- Minimally Invasive Procedure Could Help Patients Avoid Thyroid Surgery
- Self-Driving Mobile C-Arm Reduces Imaging Time during Surgery
- AR Application Turns Medical Scans Into Holograms for Assistance in Surgical Planning
- Imaging Technology Provides Ground-Breaking New Approach for Diagnosing and Treating Bowel Cancer
- CT Coronary Calcium Scoring Predicts Heart Attacks and Strokes
- AI Model Detects 90% of Lymphatic Cancer Cases from PET and CT Images
- Breakthrough Technology Revolutionizes Breast Imaging