Novel Breast Density Technology Demonstrated at ECR 2015

By MedImaging International staff writers
Posted on 16 Mar 2015
A study using a new, automated, area-based percent breast density measurement algorithm to assess mammographic breast density, using “for demonstration” full-field digital mammography (FFDM) images, was presented at the 2015 European Congress of Radiology (ECR) in Vienna (Austria). The new breast density measures could be used by researches for the development of personalized breast screening protocols.

The study used face-validity to assess 1,823 images, and compared the algorithm to visual assessments by radiologists specializing in mammography. The radiologists assessed density using the FFDM images, and validated them as 5% increments using the Intra-class Correlation Coefficient (ICC), and the BI-RADS 4-level classifications using the Kappa Statistic. ICCs and Bland Altman plots were used to evaluate internal reliability and agreement between CC and MLO views on 2,372 for presentation FFDM images, and density measurements from left and right mammography views using the new algorithm.

The results demonstrated that the Densitas (Halifax, Nova Scotia, Canada) Research Edition algorithm showed almost perfect internal reliability between left and right views, and between Cranio-Caudal (CC) and Medio-Lateral Oblique (MLO) views of the same breast, and excellent agreement with radiologists' visual assessments. The Bland-Altman plots showed narrow upper and lower limits of agreement between CC and MLO views, and negligible bias.

Related Links:

Densitas





Ultrasound Table
Women’s Ultrasound EA Table
X-ray Diagnostic System
FDX Visionary-A
New
Radiology Monitor
Barco MDNC-12130 Nio Fusion 12MP Radiology Monitor
X-Ray Generator
Advantage Plus Generators

Latest Radiography News

AI Tool Predicts Five-Year Breast Cancer Risk from Mammograms
16 Mar 2015  |   Radiography

AI Mammography Tools Detect Early Breast Cancer Signs Years Before Diagnosis
16 Mar 2015  |   Radiography

Rapid X-Ray Test Quantifies Pulmonary Regurgitation After Tetralogy of Fallot Repair
16 Mar 2015  |   Radiography