Ultrasonic Detection of Liver Stiffness a Useful Screening and Prognostic Test

By MedImaging International staff writers
Posted on 23 Feb 2010
Researchers from France and Hong Kong determined that transient elastography (TE), a noninvasive, ultrasound imaging modality, can be accurately performed in the majority of patients with nonalcoholic fatty liver disease (NAFLD) to exclude advanced fibrosis.

The findings of this study, funded by the Chinese University of Hong Kong, appear in the February 2010 issue of the journal Hepatology. NAFLD is the most common cause of liver disease worldwide. Determining a prognosis for this condition is difficult, as there are no clear predictors of whether NAFLD will progress to nonalcoholic steatohepatitis (NASH), which can lead to cirrhosis and other complications.

Liver biopsy is the standard for diagnosing NASH and fibrosis, but this procedure can be risky and samples only a small percentage of liver tissue. According to the U.S. National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK), part of the National Institutes of Health (NIH; Bethesda, MD, USA), biopsy carries a small risk of hemorrhage, puncture of other internal organs, infection, and spread of cancer cells. Transvenous liver biopsy carries an additional risk of adverse reaction to the contrast material.

To meet the urgent need for noninvasive alternatives to liver biopsy, a research team led by Victor de Lédinghen, M.D., Ph.D., from the Service d'Hépato-Gastroentérologie, Centre d' Investigation de la Fibrose hépatique, Hôpital Haut Lévesque (Bordeaux, Pessac, France), conducted an evaluation of the accuracy of TE and biochemical tests for the diagnosis of fibrosis and cirrhosis in NAFLD patients. "Transient elastography by Fibroscan is a noninvasive method for the diagnosis of liver fibrosis…Nevertheless, NAFLD patients are underrepresented in previous validation studies,” explained Dr. de Lédinghen. The team also examined liver stiffness in association with hepatic steatosis, inflammation, and obesity, and set out to identify factors associated with discordance between liver stiffness measurements (LSM) and histology.

The Fibroscan technology used in this study was developed by EchoSens (Paris, France). Using the device, a mechanical pulse is generated at the skin surface, which is propagated through the liver. The velocity of the wave is measured by ultrasound. The velocity is directly correlated to the stiffness of the liver, which in turn reflects the degree of fibrosis--the stiffer the liver is the greater the degree of fibrosis. The technique is used to quantify hepatic fibrosis in a totally noninvasive and painless manner, with no contra-indications for the patient.

The research team evaluated 246 patients from two ethnic groups from two hospitals in France and Hong Kong with valid LSM acquisitions and satisfactory liver biopsy specimens. Men who consumed more than 30 g of alcohol per week and women who consumed more than 20 g of alcohol per week were excluded. Patients with secondary causes of hepatic steatosis (e.g., chronic use of systemic corticosteroids), positive hepatitis B surface antigen or anti-hepatitis C virus antibody, or histologic evidence of other concomitant chronic liver diseases were also excluded. Since the aim of transient elastography was to diagnose significant fibrosis and early cirrhosis, patients with clinical and radiologic evidence of cirrhosis were excluded.

Researchers found that successful measurement could be obtained in over 97% of patients with BMI below 30 kg/m2 and 75% of obese patients. LSM was not affected by hepatic steatosis, necroinflammation, and obesity. Most discordance between TE and histology occurred in patients with short liver biopsy lengths and mild or no fibrosis. In addition, TE had superior performance to other noninvasive biochemical tests in diagnosing advanced fibrosis and cirrhosis.

"The adoption of transient elastography could potentially spare two-thirds of NAFLD patients from liver biopsies. Since the prevalence of NAFLD is high in many affluent countries, this approach would be cost-saving,” speculated Dr. de Lédinghen.

Dr. de Lédinghen also cautioned that while TE has a high negative predictive value, the positive predictive value of TE and other noninvasive tests to diagnose advanced fibrosis in NAFLD patients remains modest. He stated, "The main value of these tests is to exclude advanced fibrosis as screening tests. Based on our data, it is reasonable to consider liver biopsy in patients whose LSM is 7.9 kPa or above.”

Prof. Leon Adams, an associate professor at the University of Western Australia (Perth), and author of an editorial in the same issue of Hepatology, agreed, stating, "de Lédinghen et al have provided valuable data regarding the use of TE in NAFLD patients. Its strength appears to be excluding advanced fibrosis and cirrhosis; however, there are a number of issues that need to be clarified before it is routinely utilized in the clinical setting.” Prof. Adams pointed out issues in successfully conducting TE evaluations on obese patients, varying results due to diverse patient populations, and the fact that cost and availability may play a role in the decision to employ TE and other noninvasive tests in the future.

Related Links:
Chinese University of Hong Kong
Hôpital Haut Lévesque
EchoSens
University of Western Australia




New
Gold Member
X-Ray QA Meter
T3 AD Pro
New
40/80-Slice CT System
uCT 528
New
Doppler String Phantom
CIRS Model 043A
New
Gold Member
X-Ray QA Meter
T3 RG Pro

Latest Ultrasound News

Wearable Ultrasound Patch Enables Continuous Blood Pressure Monitoring

AI Image-Recognition Program Reads Echocardiograms Faster, Cuts Results Wait Time

Ultrasound Device Non-Invasively Improves Blood Circulation in Lower Limbs