Ultrasound Should Be Used First Detecting Acute Appendicitis

By MedImaging staff writers
Posted on 09 Jun 2008
Color Doppler ultrasound, not computed tomography (CT), should be the first imaging modality used for adult patients with suspected acute appendicitis, a new study emphasizes.

The study of 420 medical records found that ultrasound correctly denied acute appendicitis in 303 of 312 adult patients, meaning it had a 97% specificity rate, according to Diana Gaitini, M.D., from Rambam Health Care Campus (Haifa, Israel). "When the patient does not have acute appendicitis, the negative result of the color Doppler ultrasound examination is highly confident,” she said. On the other hand, ultrasound's sensitivity rate was 74%, meaning it missed the diagnosis in 23 of 89 patients, Dr. Gaitini reported. Ultrasound was inconclusive in 17 patients.

"We performed CT in 132 patients because the ultrasound examination was inconclusive or the patient was showing classical signs and symptoms of acute appendicitis even though the ultrasound examination was negative,” said Dr. Gaitini. CT correctly diagnosed acute appendicitis in 38 of 39 patients (99% sensitivity rate) and correctly denied acute appendicitis in all 92 patients (100% specificity rate), said Dr. Gaitini. CT was inconclusive in one patient.

"CT has a slightly higher specificity rate and a higher sensitivity rate than ultrasound, but ultrasound can help the radiologist make a definitive diagnosis in most patients,” Dr. Gaitini said. "The higher diagnostic performances of CT need to be evaluated against its disadvantages. Lack of radiation exposure [which is especially important in a population of mostly young patients], higher availability, lower cost and high specificity of color Doppler ultrasound are the main reasons for trying ultrasound first.”

The study was published in the May 2008 issue of the American Journal of Roentgenology.


Related Links:
Rambam Health Care Campus

New
Gold Member
X-Ray QA Meter
T3 AD Pro
New
Ultrasound Imaging System
P12 Elite
Silver Member
Radiographic Positioning Equipment
2-Step Multiview Positioning Platform
Imaging Table
CFPM201

Latest Ultrasound News

Wearable Ultrasound Patch Enables Continuous Blood Pressure Monitoring

AI Image-Recognition Program Reads Echocardiograms Faster, Cuts Results Wait Time

Ultrasound Device Non-Invasively Improves Blood Circulation in Lower Limbs