We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

MedImaging

Download Mobile App
Recent News Radiography MRI Ultrasound Nuclear Medicine General/Advanced Imaging Imaging IT Industry News

Single Reader with CAD More Effective than Double Reading of Mammograms

By MedImaging staff writers
Posted on 03 Mar 2008
Single reading of screening mammograms with computer-aided detection (CAD) has been found to be more effective than double reading and yields fewer false-positives than the first reader in a double reading program, according to a new study. Furthermore, the readings with CAD had a considerably lower recall rate than double reading.

The double reading method consisted of the mammogram being first read by sub-specialized mammographers, with the second reading performed by either a specialist or a general radiologist who is certified in mammography. Single reading with CAD was performed by sub-specialized mammographers.

The study, conducted by researchers from Charlotte Radiology (Charlotte, NC, USA) compared the recall rate, sensitivity, positive predictive value (PPV), and cancer detection rate of single reading with CAD to double reading, and to the first reader in the double reading program in 231,221 mammograms from 2001-2005. The study revealed that single reading with CAD was as effective at finding cancers as double reading and had a lower recall rate.

"Because double reading is time-consuming and not generally reimbursed, CAD has become increasingly popular in the United States as an alternative way to increase sensitivity,” said Matthew Gromet, M.D., author of the study.

According to the study, statistically significant results included a lower recall rate with CAD compared to double reading (10.6% vs. 11.9%), increased sensitivity with CAD compared to the first reader (90.4% vs. 81.4%), and increased recall rate with CAD compared with the first reader (10.6% vs. 10.2%). The sensitivity of single reading with CAD was slightly higher than double reading (90.4% vs. 88.0%), although this difference did not attain statistical significance.

"With manpower and cost constraints limiting the use of double reading, CAD appears to be an effective and more widely accessible alternative that provides a lower recall rate and equal or possibly higher sensitivity,” said Dr. Gromet.

The findings of this study are slated to appear in the April 2008 issue of the American Journal of Roentgenology.


Related Links:
Charlotte Radiology

New
Gold Member
X-Ray QA Meter
T3 AD Pro
New
Transducer Covers
Surgi Intraoperative Covers
New
Gold Member
X-Ray QA Meter
T3 RG Pro
New
40/80-Slice CT System
uCT 528

Latest Imaging IT News

New Google Cloud Medical Imaging Suite Makes Imaging Healthcare Data More Accessible

Global AI in Medical Diagnostics Market to Be Driven by Demand for Image Recognition in Radiology

AI-Based Mammography Triage Software Helps Dramatically Improve Interpretation Process