Super-Resolution PET Technique Enhances Brain Imaging

By MedImaging International staff writers
Posted on 08 Jul 2021
A new study shows how combining position emission tomography (PET) with an external head-motion tracking device can create highly detailed images of the brain.

Researchers at Institut Polytechnique de Paris (France), Massachusetts General Hospital (MGH; Boston, USA), and other institutions conducted a study that aimed to use super-resolution (SR) to improve PET image resolution by exploiting spatial sampling information obtained from multiple acquisitions of the same object. To do so, they used the high-resolution infra-red (IR) Polaris Vega tracking camera, which has a tracking accuracy of up to 0.12 mm isotropic and a 60 Hz frame rate.

Image: The same Hoffman phantom PET slice reconstructed with different imaging techniques (Photo courtesy of Gordon Center for Medical Imaging)
Image: The same Hoffman phantom PET slice reconstructed with different imaging techniques (Photo courtesy of Gordon Center for Medical Imaging)

A transformation linking the Polaris and scanner coordinates space to the same reference object, using squares minimization, was then used to spatially align the two instruments. To enable SR, a PET reconstruction algorithm was developed that incorporated the high-resolution tracking data from the Polaris Vega to correct motion for measured line of responses (LORs) on an event-by-event basis. Simulation models were then conducted using a Hoffman phantom and a rhesus monkey.

The results showed that for both Hoffman phantom and primate studies, SR reconstruction yielded PET images with visibly increased spatial resolution, allowing for improved visualization of small cortical and subcortical brain phantom structures. Overall, the SR method achieved better noise control than the static reconstruction with the same voxel size. For the Hoffman phantom, the SR images showed improved correspondence with the high-resolution CT, compared to conventional methods. The study was presented at the Society of Nuclear Medicine and Molecular Imaging virtual annual meeting, held during June 2021.

“This work shows that one can obtain PET images with a resolution that outperforms the scanner's resolution by making use, counterintuitively perhaps, of usually undesired patient motion,” said Yanis Chemli, MSc, PhD, of the MGH Gordon Center for Medical Imaging. “Our technique not only compensates for the negative effects of head motion on PET image quality, but it also leverages the increased sampling information associated with imaging of moving targets to enhance the effective PET resolution.”

PET is a nuclear medicine imaging technique that produces a 3D image of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide tracer. Tracer concentrations within the body are then constructed in 3D by computer analysis. In more modern PET-CT scanners, 3D imaging is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine.


Related Links:
Institut Polytechnique de Paris
Massachusetts General Hospital



Gold Member
Solid State Kv/Dose Multi-Sensor
AGMS-DM+
Compact C-Arm with FPD
Arcovis DRF-C R21
Ultrasound Doppler System
Doppler BT-200
Under Table Shield
3 Section Double Pivot Under Table Shield

Latest General/Advanced Imaging News

New AI Method Captures Uncertainty in Medical Images

CT Coronary Angiography Reduces Need for Invasive Tests to Diagnose Coronary Artery Disease

Novel Blood Test Could Reduce Need for PET Imaging of Patients with Alzheimer’s